{"product_id":"fronius-primo-5-0-1","title":"Fronius Primo 5.0-1","description":"\u003ch2\u003eFronius Primo 5.0-1\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTHE COMMUNICATIVE INVERTER FOR OPTIMISED ENERGY MANAGEMENT.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eWith power categories ranging from 3.0 to 8.2 kW, the Fronius Primo perfectly complements the SnapINverter generation. This single-phase, transformerless device is the ideal inverter for private households. Its innovative SuperFlex Design provides maximum flexibility in system design, while the SnapINverter mounting system makes installation and maintenance as easy as possible. The communication package included as standard with WLAN, energy management, numerous interfaces, and much more besides, makes the Fronius Primo a communicative inverter for owner-occupiers.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"text textImage img-right\" data-component-anchor-id=\"anc_\"\u003e\n\u003cdiv class=\"img-wrap\"\u003e\n\u003cfigure\u003e\u003cpicture\u003e\u003c\/picture\u003e\n\u003cfigcaption\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text-wrap\"\u003e\n\u003ch3\u003eSNAPINVERTER TECHNOLOGY\u003c\/h3\u003e\nThe SnapINverter generation of inverters features a simple, standardised mounting system, making installation and maintenance easier than ever. A special feature in the design of the device is that the connection area is separate from the power stage set compartment, with both being installed separately. The remarkably light connection area and all its cabling is fitted to the wall first, followed by the power stage set. The innovative hinged system makes installation and servicing extremely user-friendly. The inverter is simply placed in the wall bracket and then secured. This means that it is not necessary to remove the entire inverter for servicing, just the power stage set. All the cabling remains in place.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text textImage img-right\" data-component-anchor-id=\"anc_\"\u003e\n\u003cdiv class=\"img-wrap\"\u003e\n\u003cfigure\u003e\u003cpicture\u003e\u003csource media=\"(min-width: 1280px)\" srcset=\"\/~\/protected-media\/imported-media\/07\/93\/m-79318.png?q=70\u0026amp;iw=370\u0026amp;ih=208\u0026amp;crop=1\u0026amp;imgtype=JPG 1x, \/~\/protected-media\/imported-media\/07\/93\/m-79318.png?q=40\u0026amp;iw=740\u0026amp;ih=416\u0026amp;crop=1\u0026amp;imgtype=JPG 2x\"\u003e\u003csource media=\"(min-width: 1024px) and (max-width: 1279px)\" srcset=\"\/~\/protected-media\/imported-media\/07\/93\/m-79318.png?q=70\u0026amp;iw=286\u0026amp;ih=161\u0026amp;crop=1\u0026amp;imgtype=JPG 1x, \/~\/protected-media\/imported-media\/07\/93\/m-79318.png?q=40\u0026amp;iw=572\u0026amp;ih=322\u0026amp;crop=1\u0026amp;imgtype=JPG 2x\"\u003e\u003csource media=\"(min-width: 768px) and (max-width: 1023px)\" srcset=\"\/~\/protected-media\/imported-media\/07\/93\/m-79318.png?q=70\u0026amp;iw=226\u0026amp;ih=127\u0026amp;crop=1\u0026amp;imgtype=JPG 1x, \/~\/protected-media\/imported-media\/07\/93\/m-79318.png?q=35\u0026amp;iw=452\u0026amp;ih=254\u0026amp;crop=1\u0026amp;imgtype=JPG 2x\"\u003e\u003c\/source\u003e\u003c\/picture\u003e\n\u003cfigcaption\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"text-wrap\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv role=\"tab\" id=\"hbacc_0b738c55-4cf8-4a8a-bef5-b16a47f6088e_372160b4-7b89-436b-80c5-d56ae52046d5_\" class=\"panel-heading\"\u003e\n\u003ch3 class=\"panel-title\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv aria-labelledby=\"hbacc_0b738c55-4cf8-4a8a-bef5-b16a47f6088e_372160b4-7b89-436b-80c5-d56ae52046d5_\" role=\"tabpanel\" class=\"panel-collapse collapse in\" id=\"bacc_0b738c55-4cf8-4a8a-bef5-b16a47f6088e_372160b4-7b89-436b-80c5-d56ae52046d5_\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cdiv class=\"text\" data-component-anchor-id=\"anc_\"\u003e\n\u003cdiv class=\"text-wrap\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003eINPUT DATA\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eNumber of MPP trackers\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eMax. input current (I\u003csub\u003edc max\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e12 \/ 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eMax. short circuit current, module array\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e18 \/ 18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eDC input voltage range (U\u003csub\u003edc min\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- U\u003csub\u003edc max\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e80 - 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eFeed-in start voltage (U\u003csub\u003edc start\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eNominal input voltage (U\u003csub\u003edc,r\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e710 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eMPP voltage range (U\u003csub\u003empp min\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- U\u003csub\u003empp max\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e240 - 800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUsable MPP voltage range\u003c\/th\u003e\n\u003ctd\u003e80 - 800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of DC connections\u003c\/th\u003e\n\u003ctd\u003e2 + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eMax. PV generator power (P\u003csub\u003edc max\u003c\/sub\u003e) \u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e7,5 kWpeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOUTPUT DATA\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eAC nominal output (P\u003csub\u003eac,r\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e5000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eMax. output power (P\u003csub\u003eac max\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e5000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eAC output current (I\u003csub\u003eac nom\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e21,7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eGrid connection (U\u003csub\u003eac,r\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e1~ NPE 220\/230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eAC voltage range (U\u003csub\u003emin\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- U\u003csub\u003emax\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e180 - 270 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eFrequency (f\u003csub\u003er\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eFrequency range (f\u003csub\u003emin\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- f\u003csub\u003emax\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e45 - 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eTotal harmonic distortion\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 5 % 5=\"\" %=\"\"\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003ePower factor (cos φ\u003csub\u003eac,r\u003c\/sub\u003e)\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e0,85 - 1 ind.\/cap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eGENERAL DATA\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e645 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e431 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e204 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e21,5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eOvervoltage category (DC \/ AC)\u003csup\u003e\u003cspan\u003e \u003c\/span\u003e1)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e2 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNight-time consumption\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 w 1=\"\"\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter design\u003c\/th\u003e\n\u003ctd\u003eTransformerless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eRegulated air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eIndoors and outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature range\u003c\/th\u003e\n\u003ctd\u003e-40°C - +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermitted humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eMax. altitude\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e4.000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC connection technology\u003c\/th\u003e\n\u003ctd\u003e4x DC+ and 4x DC- screw terminals 2.5 - 16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC connection technology\u003c\/th\u003e\n\u003ctd\u003e3-pin AC screw terminals 2.5 - 16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificates and compliance with standards\u003c\/th\u003e\n\u003ctd\u003eDIN V VDE 0126-1-1\/A1, IEC 62109-1\/-2, IEC 62116, IEC 61727,\u003cbr\u003eAS 4777-2, AS 4777-3, G83\/2, G59\/3, CEI 0-21, VDE AR N 4105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eEFFICIENCY\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. efficiency (PV - grid)\u003c\/th\u003e\n\u003ctd\u003e98,1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEuropean efficiency (ηEU)\u003c\/th\u003e\n\u003ctd\u003e97,1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 5% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e80,8 \/ 82,5 \/ 82,5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 10% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e89,6 \/ 94,8 \/ 93,1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 20% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e93,4 \/ 97,2 \/ 96,2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 25% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e94,1 \/ 97,3 \/ 96,8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 30% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e94,7 \/ 97,4 \/ 97,0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 50% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e95,8 \/ 97,9 \/ 97,7 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 75% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e96,1 \/ 98,0 \/ 97,9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eη at 100% P\u003csub\u003eac,r\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e\u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003e96,2 \/ 97,9 \/ 97,9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMPP adaptation efficiency\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 99,9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003ePROTECTION DEVICES\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDC insulation measurement\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload behaviour\u003c\/th\u003e\n\u003ctd\u003eOperating point shift, power limitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC disconnector\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eINTERFACES\u003c\/h3\u003e\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eWLAN \/ Ethernet LAN\u003c\/th\u003e\n\u003ctd\u003eFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e6 inputs and 4 digital inputs\/outputs\u003c\/th\u003e\n\u003ctd\u003eInterface to ripple control receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eUSB (type A socket)\u003csup\u003e\u003cspan\u003e \u003c\/span\u003e4)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003eData logging, inverter update via USB flash drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003e2x RS422 (RJ45 socket)\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003eFronius Solar Net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eSignalling output\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003eEnergy management (floating relay output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDatalogger and web server\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv\u003eExternal input\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4)\u003c\/sup\u003e\n\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd\u003eS0 meter connection \/ Evaluation of overvoltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRS485\u003c\/th\u003e\n\u003ctd\u003eModbus RTU SunSpec or meter connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GUNMANSA","offers":[{"title":"Default Title","offer_id":51544288231739,"sku":"IN-FR-PR 5.0-1","price":33975.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/3480\/8379\/files\/86ed01b6-b743-4646-91eb-c14ffd8f1797.png?v=1786084564","url":"https:\/\/gunmansa.co.za\/id\/products\/fronius-primo-5-0-1","provider":"GUNMANSA","version":"1.0","type":"link"}